4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
aatbio(优势品牌)
主营:主营:研究并生产荧光和发光探针,信号转导研究的试剂
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > Other_biological_dyes > AAT Bioquest/Fluo-8®, sodium salt/21086/1 mg
商品详细AAT Bioquest/Fluo-8®, sodium salt/21086/1 mg
AAT Bioquest/Fluo-8®, sodium salt/21086/1 mg
AAT Bioquest/Fluo-8®, sodium salt/21086/1 mg
商品编号: 21086
品牌: aatbio
市场价: ¥85560.00
美元价: 51336.00
产地: 美国(厂家直采)
公司:
产品分类: 其他生物染料
公司分类: Other_biological_dyes
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Overview
PrinterFriendlyVersion

Ex/Em(nm)494/517
MW796.53
CAS#N/A
SolventWater
StorageF/D/L
CategoryGPCR
CalciumGPCRAssays
RelatedCalciumChannels
pHandIonIndicators
BiochemicalAssays
CalciummeasurementiscriticalfornumerousBIOLOGicalinvestigations.FluorescentprobesthatshowspectralresponsesuponbindingCa2+haveenabledresearcherstoinvestigatechangesinintracellularfreeCa2+concentrationsbyusingfluorescencemicroscopy,flowcytometry,fluorescencespectroscopyandfluorescencemicroplatereaders.Fluo-3andFluo-4aremostcommonlyusedamongthevisIBLelight-excitablecalciumindicators.However,Fluo-3AMandFluo-4AMareonlymoderatelyfluorescentinlivecellsuponesterasehydrolysis,andrequireharshcellloADIngconditionstomaximizetheircellularcalciumresponses.Fluo-8®dyesaredevelopedtoimprovecellloadingandcalciumresponsewhilemaintainingtheconvenientFluo-3andFluo-4spectralwavelengthofmaximumexcitation@~490nmandmaximumemission@~520nm.Fluo-8®AMonlyrequiresroomtemperaturewhileFluo-3AMandFluo-4AMrequire37?Ccellloading.Inaddition,Fluo-8®is2timesbrighterthanFluo-4AM,and4timesbrighterthanFluo-3AM.AATBioquestoffersasetofouroutstandingFluo-8®reagentswithdifferentcalciumbindingaffinities(Fluo-8®:Kd=389nM;Fluo-8H:Kd=232nM;Fluo-8L:Kd=1.86µM;Fluo-8FF:Kd=10µM).Wealsoofferversatilepackingsizestomeetyourspecialneeds,e.g.,1mg;10x50µg;20x50µg;HTSpackageswithnoadditionalpackagingcharge.
SpectrumAdvancedSpectrumViewer

Sorry,yourbrowserdoesnotsupportinlineSVG.RelativeIntensity(%)100806040200Sorry,yourbrowserdoesnotsupportinlineSVG.
Sorry,yourbrowserdoesnotsupportinlineSVG.Sorry,yourbrowserdoesnotsupportinlineSVG.
Movemouseovergridtodisplaywavelength&intensityvalues.

300
400
500
600
700
800
900
Wavelength(nm)


Thisprotocolonlyprovidesaguideline,andshouldbemodifiedaccordingtoyourspecificneeds.

UseofFluo-8®AMEsters

1.LoadCellswithFluo-8®AMEsters:

AMestersarethenon-polarestersthatreadilycrosslivecellmembranes,andrapidlyhydrolyzedbycellularesterasesinsidelivecells.AMestersarewidelyusedforloadingavarietyofpolarfluorescentprobesintolivecellnon-invasively.However,cautionsmustbeexcisedwhenAMestersareusedsincetheyaresusceptibletohydrolysis,particularlyinsolution.Theyshouldbereconstitutedjustbeforeuseinhigh-quality,anhydrousdimethylsulfoxide(DMSO).DMSOstocksolutionsmaybestoreddesiccatedat–20°Candprotectedfromlight.Undertheseconditions,AMestersshouldbestableforseveralmonths.

FollowingisourrecommendedprotocolforloadingFluo-8®AMestersintolivecells.Thisprotocolonlyprovidesaguideline,andshouldbemodifiedaccordingtoyourspecificneeds.

a)      Preparea2to5mMstocksolutionofFluo-8®AMestersinhigh-quality,anhydrousDMSO.

b)      Onthedayoftheexperiment,eitherdissolveFluo-8®inDMSOorthawanaliquotoftheindicatorstocksolutiontoroomtemperature.Prepareaworkingsolutionof1to10µMinHanksandHepesbuffer(HHBS)orthebufferofyourchoicewith0.02%Pluronic®F-127.Formostofcelllines,Fluo-8®reagentswithaconcentrationrangingfrom4-5uMarerecommended.Theexactconcentrationoftheindicatorrequiredforcellloadingmustbedeterminedempirically.Toavoidanyartifactscausedbyoverloadingandpotentialdyetoxicity,itisrecommendedtousetheminimaldyeconcentrationthatcangeneratesufficientsignalstrength.

Note:ThenonionicdetergentPluronic®F-127issometimesusedtoincreasetheaqueoussolubilityofFluo-8®AMesters. AvarietyofPluronic®F-127solutionscanbepurchasedfromAATBioquest.

c)      Ifyourcellscontainingtheorganicanion-transports,probenecid(1–2.5mM)orsulfinpyrazone(0.1–0.25mM)maybeaddedtothecellmediumtoreduceleakageofthede-esterifiedindicators.

Note:AvarietyofReadiUse™probenecidincludingwatersolublesodiumsaltandstABIlizedsolutioncanbepurchasedfromAATBioquest.

d)      Addequalvolumeofthedyeworkingsolution(fromStepborc)intoyourcellplate.

e)      Incubatethedye-loadingplateatacellincubatororroomtemperaturefor20minutestoonehour.

Note:Decreasingtheloadingtemperaturemightreducethecompartmentalizationoftheindictor.

f)       ReplacethedyeworkingsolutionwithHHBSorbufferofyourchoice(containingananiontransporterinhibitor,suchas2.5mMprobenecid,ifapplicable)toremoveexcessprobes.

g)      RuntheexperimentsatEx/Em =490/525nm

 

UseofScreenQuest™Fluo-8NWCalciumAssayKitsforHTSApplications

GPCRactivationcanbedetectedbydirectmeasurementofthereceptormediatedcAMPaccumulation,orchangesinintracellularCa2+concentration.GPCRtargetsthatcoupleviaGqproduceanincreaseinintracellularCa2+thatcanbemeasuredusingacombinationofFluo-8®reagentsandafluorescencemicroplatereader.Thefluorescenceimagingplatereaders(suchas,FLIPR™,FDSSorBMGNovoStar™)haveacooledCCDcameraimagingsystemwhichcollectsthesignalfromeachwellofamicroplate(both96and384-well)simultaneously.Theseplatereaderscanreadatsub-secondintervals,whichenablesthekineticsoftheresponsetobecaptured,andhasanintegratedpipettorthatmaybeprogrammedforsuccessiveliquidadditions.BesidestheirrobustapplicationsforGPCRtargets,ourScreenQuest™Fluo-8CalciumAssayKitscanbealsousedforcharacterizingcalciumionchannelsandscreeningcalciumionchannel-targetedcompounds.



Figure2.CarbacholDoseResponsewasmeasuredinHEK-293cellswithScreenQuest™Fluo-8NWAssaykitandFluo-4NWAssayKit.HEK-293cellswereseededovernightat40,000cells/100µL/wellina96-wellblackwall/clearbottomcostarplate.Thegrowthmediumwasremoved,andthecellswereincubatedwith,respectively,100µLoftheScreenQuest™Fluo8-NWcalciumassaykitandFluo-4NWkit(accordingtothemanufacturer’sinstructions)for1houratroomtemperature.Carbachol(25µL/well)wasaddedbyNOVOstar(BMGLabTech)toachievethefinalindicatedconcentrations.TheEC50ofFluo-8NWisabout1.2uM.

ComparedtoothercommercialcalciumassaykitsthateitherbasedonFluo-3orFluo-4,ourScreenQuest™CalciumAssayKitshavethefollowingadvantagesforHTSapplications:

BroadApplications:workwithbothGPCRandcalciumchanneltargets.

ConvenientSpectralWavelengths:maximumexcitation@~490nm;maximumemission@~514nm.

FlexibleDyeLoading:dyeloadingatroomtemperature(ratherthan37ºCrequiredforFluo-4AM).

NoWashRequiredandNoQuencherInterferencewithYourTargets.

RobustPerformance:enablecalciumassaysthatareimpossiblewithFluo-4AMorFluo-3AM.

StrongestSignalIntensity:2timesbrighterthanthatofFluo-4AM;4timesbrighterthanthatofFluo-3AM.

 

UseofFluo-8®Salts

Calciumcalibrationcanbecarriedoutbymeasuringthefluorescenceintensityofthesaltform(25to50µMinfluorescencemicroplatereaders)oftheindicatorsinsolutionswithpreciselyknownfreeCa2+concentrations.Calibrationsolutionscanbeusedbasedon30mMMOPSEGTACa2+buffer.Ingeneral,watercontainstraceamountofcalciumion.Itishighlyrecommendedtouse30mMMOPS+100mMKCl,pH7.2asbuffersystem.Onecansimplymakea0and39µMcalciumstocksolutionsaslistedbelow,andthese2solutionsareusedtomakeaserialsolutionofdifferentCa2+concentrations

A.0µMcalcium:30mMMOPS+100mMKCl,pH7.2buffer+10mMEGTA

B.39µMcalcium:30mMMOPS+100mMKCl,pH7.2buffer+10mMEGTA+10mMCaCl2

 

TodetermineeitherthefreecalciumconcentrationofasolutionortheKdofasingle-wavelengthcalciumindicator,thefollowingequationisused:

[Ca]free=Kd[F─Fmin]/Fmax─F]

WhereFisthefluorescenceintensityoftheindicatorataspecificexperimentalcalciumlevel,FministhefluorescenceintensityintheabsenceofcalciumandFmaxisthefluorescenceintensityofthecalcium-saturatedprobe.

 

Thedissociationconstant(Kd)isameasureoftheaffinityoftheprobeforcalcium.Thecalcium-bindingandspectroscopicpropertiesoffluorescentindicatorsvaryquitesignificantlyincellularenvironmentscomparedtocalibrationsolutions.InsituresponsecalibrationsofintracellularindicatorstypicallyyieldKdvaluessignificantlyhigherthaninvitrodeterminations.InsitucalibrationsareperformedbyexposingloadedcellstocontrolledCa2+buffersinthepresenceofionophoressuchasA-23187,4-bromoA-23187andionomycin.Alternatively,cellpermeabilizationagentssuchasdigitoninorTriton®X-100canbeusedtoexposetheindicatortothecontrolledCa2+levelsoftheextracellularmedium.TheKdvaluesofFluo-8®reagentsarelistedinTable1foryourreference.

References&Citations
CitationExplorer
Fluo-8®AMhasbeenwidelyusedtostudycalciumionsincriticalbiologicalprocessesacrossaspanofdifferentdisciplines.Suchprocessesinclude,butarenotlimitedto,Gprotein-coupledreceptorsignalingpathways,calciumionchannelactivity,intracellular/cytosolicCa2+fluxandactivationofcellreceptors.

Below,youmayfindasmallsamplingofspecificFluo-8®AMapplicationssortedbyfieldofstudy.ToinquireaboutapotentialapplicationofFluo-8®AM,ortoconsultwithourfluorescentdyespecialists,pleasecontactusatsupport@aatbio.comor1-800-990-8053.

InOncology,Fluo-8®AMhasbeenusedtostudy:
»BreastcancercellsbymonitoringintracellularCa2+fluxassociatedwithapoptosisandinhibitionby2-aminoethoxydiphenylborate[1]
»Antitumoractivitybywayofthioredoxin-bindingprotein2anditsdependenceonintracellularcalciumconcentration[2]
»Bcl-1andBcl-2regulationthroughcharacterizationofcytosolictransportasquantifiedbycalciumflux[3]
»Ca2+influxandCa2+channelactivityinNCI-H460cellsasaparameterformonitoringprogressionofnon-smallcelllungcancer[4]
»Ca2+releasebyHN4cellsandCLIC4upregulationofapoptosisthroughmitochondrialandendoplasmicreticulumpathways[5]

InCardiology,Fluo-8®AMhasbeenusedtostudy:
»Low-energyfar-fieldstimulationasatherapyfortachycardiaandfibrillation[6]
»Calciumfluxduringcalciumsparksinventricularmyocytes[7]
»Cardiacconductionasafunctionofcellrigidityinthecontextofcardiovasculardisease[8]
»DiastolicCa2+transientsincardiacmyocytesandSR-luminalandfreecytoplasmicCa2+concentrations[9]
»Sphingosine-1-phosphate(S1P)receptoractivationinvalvularinterstitialcellsasdetectedbycytosolicCa2+flux[10]

InNeurobiology,Fluo-8®AMhasbeenusedtostudy:
»HippocampalCA1neurons,visualizatingneuronstoinvestigatetheroleofamyloid-βintheprogressionofAlzheimer"sdisease[11]
»CytosolicCa2+concentrationsinHEK293cellsanditsregulatoryeffectonAβ1-42andhAmylinandassociatedsignalingpathways[12]
»Gprotein-coupledreceptors(GPRs)inresponsetocannabinoidsinpresynapticCA3orpostsynapticCA1pyramidalcells[13]
»Medullaryinterneuronsanddendriticcalciumactivityinregardstoinspiratorybursts[14]
»N2acellactivationbyhistamine,asmonitoredbyincreasesinintracellularCa2+concentrations[15]

InStemCells,Development&Differentiation,Fluo-8®AMhasbeenusedtostudy:
»Inductionofpluripotentstemcells(iPSCs)intofunctioningcardiaccells,asvalidatedbyCa2+fluxandmembranepotential[16]
»CXCR4andCXCR7receptorsinTcellsandtheirroleincellsurvivalandchemotaxis[17]
»Ca2+uptakebymyocytesderivedfromhumaninducedpluripotentstemcellsduringpathogenesisofDuchennemusculardystrophy[18]
»AgoNIST-inducedcalciumtransientsindifferentiationofratbonemarrowmesenchymalstemcellsintosmoothmusclecells[19]
»CalciumchannelblockadesandtheireffectoncardiacProgenitorcellproliferationanddifferentiation[20]

ViewMoreCitations
品牌介绍
美国AAT Bioquest Inc.(前身是ABD Bioquest,Inc.)是一家为从事生命科学研究、诊断研发及药物开发的科学家研发、生产和销售生物分析研究试剂和试剂盒的公司。公司致力于光谱学检测领域,包括吸收(颜色)、荧光和发光技术。AAT Bioquest的产品帮助全世界的科学家和生物医药研究者更好的了解生物化学、免疫学、细胞生物学和分子生物学等领域。AAT Bioquest会不断研发新产品,快速地丰富各个领域的产品。 1)提供反应探针和发光探针,生物素和端粒酶能够应用于标记药物小分子和生物聚合物,如蛋白、核酸以及其他碳水化合物; 2)研究并生产荧光和发光探针用于检测蛋白,核酸和活细胞; 3)不断推出新型的荧光和发光探针用于检测多种酶,特别是检测水解酶和氧化还原酶类; 4)致力于开发用于信号转导研究的试剂; 5)提供生理和神经探针,特别是钙离子指示剂和膜电位探针。
品牌分类
淋巴细胞信号传导 GPCR抗体 羰基活性生物素 细胞代谢 胺反应生物素 链霉亲和素结合物 生物素化抗IgGs 乙酰基特异性抗体 细胞骨架抗体
联络我们
服务热线:4000-520-616
(限工作日9:00-18:00)
QQ :1570468124
手机:18915418616